Pile Load Testing Deep Foundation High Strain Dynamic Load Testing Instrument
Application:
High strain bearing capacity detection of pile
Low strain pile integrity detection by reflected wave method (optional)
Applicable standards
Standard Test Method for High Strain Dynamic Testing of Deep Foundations ASTM D4945-12
Technical Code for Detection of Building Foundation Pile JGJ 106-2014
Dynamic Testing Technology Regulations on Highway Engineering Foundation Pile JTG/T F81-01-2004
Nondestructive Detection Code for Railway Engineering Foundation Pile TB 10218-2008
Working Principle:
The tester will provide prediction on the pile bearing capacity, pile integrity, driving stresses and hammer performance for a given pile penetration. It is a relative low cost type of pile testing compared to static load test (MLT or CRP). The testing technique is quick and accurate.
Software Feature
1. The fitting analysis of high strain bearing capacity detection of single pile can be carried out;
2. Fitting parameters can be adjusted conveniently and quickly and the recommended parameters table is provided so as to grasp the fitting skills quickly;
3. The simulated static load test curve and pile soil resistance distribution diagram can be output;
4. Original curve and fitting calculation curve can be output in a variety of modes;
Application:
High strain bearing capacity detection of pile
Low strain pile integrity detection by reflected wave method (optional)
Applicable standards
Standard Test Method for High Strain Dynamic Testing of Deep Foundations ASTM D4945-12
Technical Code for Detection of Building Foundation Pile JGJ 106-2014
Dynamic Testing Technology Regulations on Highway Engineering Foundation Pile JTG/T F81-01-2004
Nondestructive Detection Code for Railway Engineering Foundation Pile TB 10218-2008
Working Principle:
The tester will provide prediction on the pile bearing capacity, pile integrity, driving stresses and hammer performance for a given pile penetration. It is a relative low cost type of pile testing compared to static load test (MLT or CRP). The testing technique is quick and accurate.
Software Feature
1. The fitting analysis of high strain bearing capacity detection of single pile can be carried out;
2. Fitting parameters can be adjusted conveniently and quickly and the recommended parameters table is provided so as to grasp the fitting skills quickly;
3. The simulated static load test curve and pile soil resistance distribution diagram can be output;
4. Original curve and fitting calculation curve can be output in a variety of modes;
Model | High Strain |
Display method | 8.4-inch true-color LCD screen Resolution: 800×600 (adjustable backlight) |
Storage capacity | 16G electronic hard disk |
Master control system | Low power embedded system Basic frequency≥1GHz Memory: 512M |
Sampling interval | High strain: 10-500μs multi-level adjustable Low strain: 5-1000μs continuous adjustable |
Floating point magnification | 1~256 |
Recording length | 1k |
A/D conversion accuracy | 24-bit instantaneous floating point |
System noise voltage | <20μV |
Dynamic range | ≥100dB |
Data export method | USB |